AS 2870 & AS 3600 COMPLIANT

Concrete Footing & Pier Calculator Australia

Calculate exact concrete volume in cubic metres (m³), trench mesh lengths (3-L11TM & 4-L12TM), bar chairs, spoil bulking, and truckloads for residential strip footings, isolated column pads, and cylindrical bored piers.

Concrete Footing & Pier Calculator

Footing & Pier Specifications

AS 2870 Compliant
1. Strip Footing Geometry
m
Continuous footing run
mm
Min 300mm–400mm (AS 2870)
mm
Depth into natural clay/sand
%
10%–15% for rough ground
2. Trench Mesh Steel (AS/NZS 4671)
3. Ready-Mix Rate
$
Delivered rate from Boral/Hanson/Holcim

Australian Footing Engineering, Trench Mesh & Soil Depth Guide

Pouring footings without an accurate trench take-off is asking for trouble. Excavated trenches in raw dirt are never perfectly laser-straight; sidewalls cave in, backhoe teeth cut uneven widths, and unformed trenches drink between 10% and 15% more wet mix than engineering drawings state. Getting your trench volume, steel mesh laps, and soil spoil clear before calling the batch plant protects your job margin and passes council framing inspections under AS 2870.

Footing & Pier Volume Calculation Formulas

Footing concrete is calculated using basic geometry converted to metres, with a necessary excavation buffer added to accommodate ground irregularities.

Continuous Strip Footing Formula: Volume (m³) = Length (m) × (Width in mm ÷ 1000) × (Depth in mm ÷ 1000) × 1.10 (Buffer)
Cylindrical Bored Pier Formula: Volume (m³) = π × (Diameter ÷ 2000)² × (Depth in mm ÷ 1000) × Quantity × 1.10

For example, a residential brick-veneer perimeter measuring 30 lineal metres of trench cut at 400mm width and 450mm depth:

  • Theoretical Volume: 30.0m × 0.40m × 0.45m = 5.40 m³
  • With 10% Trench Buffer: 5.40 m³ × 1.10 = 5.94 m³ → Order 6.0 m³ (one standard agitator truck load).
  • Trench Mesh: 30m ÷ 5.5m effective cover per 6m length = 6 × 6.0m lengths of 4-L11TM.

AS 2870 Soil Reactivity & Footing Depths

In Australia, residential foundation depths are strictly governed by your site soil classification report under AS 2870 Clause 3.1. Reactive clay soils swell during wet winters and shrink during dry summers, exerting massive lifting pressure on shallow footings.

AS 2870 Soil ClassGround DescriptionTypical Movement (Ys)Min Strip Footing Depth
Class AStable sand or solid bedrock0mm (negligible)300mm into firm ground
Class SSlightly reactive clay / silt0mm – 20mm400mm into natural clay
Class MModerately reactive clay20mm – 40mm500mm – 650mm into clay
Class H1 / H2Highly reactive clay soil40mm – 75mm750mm – 1000mm+ or bored piers
Class EExtremely reactive deep clay75mm+ (extreme movement)Engineered piers down to bedrock
Class PProblem site (soft fill, swamp, slope)Variable / uncontrolledEngineered specific design only

Trench Mesh Steel Sizing (3-L11TM vs 4-L12TM)

Trench mesh (complying with AS/NZS 4671) consists of longitudinal high-strength ribbed deformed bars spaced at 100mm cross-centers. The designation code reveals its physical makeup:

  • 3-L11TM: 3 longitudinal wires of 11mm deformed bar. The cage width is 200mm, designed to sit inside 300mm to 350mm wide trenches.
  • 4-L11TM: 4 longitudinal wires of 11mm deformed bar. The cage width is 300mm, designed for standard 400mm to 450mm wide trenches.
  • 4-L12TM: 4 longitudinal wires of 12mm deformed bar. Used for heavy double-brick construction, high-wind zones, or reactive Class H soils.
  • Corner Overlaps: Always overlap straight runs by 500mm. At 90-degree corners, wire in pre-bent 12mm L-bars (500mm × 500mm legs) to prevent corner shear fractures.

Comparing Strip Footings, Pad Footings & Bored Piers

Different structural components require different footing designs:

  • Strip Footings: Continuous concrete trenches beneath perimeter brickwork or external load-bearing timber framing. They spread building weight evenly along the trench line.
  • Isolated Pad Footings: Square or rectangular mass concrete pads dug directly under verandah posts, pergola columns, or structural steel beams. They transfer concentrated vertical point loads into subsoil.
  • Bored Cylinder Piers: Vertical round shafts drilled with an auger attachment down through soft topsoil until they anchor into solid rock or dense clay. The house slab or subfloor stumps then sit on top of these concrete columns.

Excavation Soil Bulking Factor

One common surprise for builders and landscapers is how much dirt comes out of a footing trench. Undisturbed virgin soil is compacted by thousands of years of natural overburden. When backhoe teeth rip it out, air enters the material, causing the soil volume to bulk up by 20% to 30%.

If your footing trench measures 10 m³ net volume in the ground, expect roughly 12.5 m³ to 13.0 m³ of loose soil to haul away. Factor this bulking factor into your skip bin orders or tip truck hire to avoid leaving heaps on site.

Pre-Pour Trench Inspection Checklist

Before ordering the agitator truck or calling the building certifier:

  • Clear Loose Spoil & Slumped Dirt: Shovel out all collapsed trench sidewall soil from the trench bottom. Footings must rest on undisturbed solid ground, not loose backfill.
  • Pump Out Trapped Rainwater: Never pour concrete into a muddy, waterlogged trench. Slurry mixes with wet concrete and severely dilutes structural 25MPa strength.
  • Verify 50mm Mesh Cover: Confirm all mesh is resting securely on 50/65mm plastic chairs and cannot touch the trench dirt when walked on during the pour.
  • Check Dial-Before-You-Dig (1100): Verify no sewer mains, stormwater pipes, or electrical conduits cross through the footing zone without proper bridging expansion sleeving.

Frequently Asked Questions

Common questions about residential concrete footings, AS 2870 embedment depths, trench mesh specifications, and spoil volume